当前位置:循环首页>正文

ODESSA试验亚组分析:血管造影、血管内超声和OCT评价药物洗脱支架和裸金属支架覆盖程度对冠状动脉疾病的长期影响

Angiographic, IVUS and OCT evaluation of the long-term impact of coronary disease severity at the site of overlapping drug-eluting and bare metal stents: a substudy of the ODESSA trial.

作者:国际循环网   日期:2010/12/6 13:48:57

国际循环网版权所有,谢绝任何形式转载,侵犯版权者必予法律追究。

BACKGROUND: A potentially adverse vascular response to overlapping drug eluting stents (DES) has been suggested in current research

    Tahara S, Bezerra HG, Sirbu V, Kyono H, Musumeci G, Rosenthal N, Guagliumi G, Costa MA.
    Harrington McLaughlin Heart and Vascular Institute, University Hospitals Case Medical Centre, Cleveland, OH 44106-5038, USA.
Abstract
    BACKGROUND: A potentially adverse vascular response to overlapping drug eluting stents (DES) has been suggested in current research.
    OBJECTIVE: To evaluate the impact of baseline disease severity at the site of stent overlap.
    METHODS AND RESULTS: This is a substudy of ODESSA, a prospective, randomised controlled trial designed to evaluate healing of overlapping stents. 71/77 patients with a total of 86 overlapping stents were studied: 25 sirolimus, 24 paclitaxel, 26 zotarolimus-eluting stents; and 11 bare metal stents (BMS). Patients were categorised into high-grade stenosis (HGS, ≥ 70% diameter stenosis) and low-grade stenosis (LGS, <70%) at the site of stent overlap. Angiography and intravascular ultrasound were performed after stent deployment and repeated at 6 months, together with additional optical coherence tomography. Images were analysed by an independent core laboratory. End points were binary restenosis, percentage neointimal hyperplasia (%NIH), mean lumen and stent areas and degree of strut coverage/apposition at overlapping stents at 6 months. Stent overlaps occurred in 49 HGS and 37 LGS. Restenosis was found in 5/6 HGS versus 0/5 LGS treated with overlapping BMS (p=0.01) and 4/43 HGS versus 0/32 LGS treated with overlapping DES. There was a trend towards higher %NIH at BMS overlap in HGS versus LGS (p=0.07). DES overlaps had lower lumen and stent areas and similar %NIH in HGS versus LGS. Any uncovered or malapposed struts occurred more often in overlapping DES at LGS than at HGS (59.4% vs 32.6%, p=0.03).
    CONCLUSIONS: Overlapping DES in normal-appearing coronary segments showed a higher incidence of uncovered or malapposed struts, while restenosis occurred exclusively in overlapping stents at HGS. These findings should be considered when deploying overlapping stents.
 

版面编辑:沈会会  责任编辑:张衡



ODESSAIVUSOCT药物洗脱支架裸金属支架覆盖程度

分享到: 更多


设为首页 | 加入收藏 | 关于我们 | 联系方式 | 招贤纳士
声明:国际循环网( www.icirculation.com)对刊载的所有文章、视频、幻灯、音频等资源拥有全部版权。未经本站许可,不得转载。
京ICP备15014970号-5  互联网药品信息服务资格证书编号(京)-非经营性-2017-0063  京公网安备 11010502033353号  增值电信业务经营许可证:京ICP证150541号
国际循环 版权所有   © 2004-2024 www.icirculation.com All Rights Reserved
公司名称:北京美赞广告有限公司 公司地址:北京市朝阳区朝阳门北大街乙12号天辰大厦1座1409 电话:010-51295530